网页 · 760 SERIES FLAME SENSORS FOR HSI Flame Sensors can be Mounted Remotely on Multiple Burners FEATURES • High quality Alumina ceramic insulator. • …
contact网页 · FLAME SENSORS & ELECTRODES FEATURES • Cycle Pilot Mercury Flame Sensors designed for 36C84 and 36C94 gas valves include adapters for competitive …
contact网页Spark Igniter, Pilot Relite kit. RTH75 & 75A infrared heaters. 12" Ignition cable included. 120 volt. Uses same mounting holes. Individually packed. - REPLACES:Roberts Gordon, CoRayVac P/N's,, …
contact网页 · (approximately 10.000 6000 volts ) until a pilot flame is sensed between the ignition electrode and ground. The Relite control detects a flame through "flame …
contact网页SPARK IGNITION pilot relite controlS 5059 Generates Spark Until a Pilot Flame is Sensed HEATING FEATURES • Generates spark pulse until flame is sensed through spark …
contact网页 · White Rodgers 5059-23 - Pilot Relite Control, 1/4" Spade Terminals, 24V Input, 1/4" Spade Terminal High Voltage Connection - Combines in One Enclosure the Functions of a 5059 Type and 5022 …
contact网页Functionally Replaces: Roberts Gordon, CoRayVac P/N's,,, 38285, 904-171 OR 904-174, 5059A-600, 5058A-7 and 5059A-500,K …
contact网页 · Generates Spark Until a Pilot Flame is Sensed FEATURES • Generates spark pulse until flame is sensed through spark electrode. • Begins sparking immediately if …
contact网页 · pilot relight control Wr 5059-23 and gas valve Wr 36C84 type 346.Are there any troubleshooting tests that I can perform on these units to confirm why the pilot keeps …
contact网页 · The current remains at a low level as long as the flame front passes ...flame sensor detects the presence of the pilot flame. If the pilot flame goes out (with the …
contact网页Generates Spark Pulse Until Flame is Sensed through Spark Electrode; Begins Sparking Immediately if Flame Extinguishes; Rugged Solid State Module Design; Spark Plug or Spike Output Configurations: Manufacturer Name : White-Rodgers: Manufacturer Part Number : 50-59-134S1: Manufacturer Part Number Additional : 5059-134: Series/Model : 5059: …
contact网页Cici Boiler Rooms, Inc. stocks all of the commonly available Gordon-Piatt ignition electrodes and flame rods. Below are the electrodes used on a Gordon-Piatt 216C pilot assembly. The 216C is the most commonly used …
contact网页 · White Rodgers 5059-134 Pilot Relite Control, 24 VAC, 0.03 amp Generates spark pulse until flame is sensed through spark electrode Begins sparking immediately if flame extinguishes Rugged solid state module design Spike terminal high voltage and 1/4" spade terminals connection
contact网页 · • Electrode. An electrical conductor used to make contact with a nonmetallic part of a circuit. (I threw in this definition because, in this case, the pilot burner hood also acts as an electrode when proving flame.) Spark ignition process. Let’s take a quick run through the sequence of operations when everything is working properly. 1.
contact网页SPARK IGNITION pilot relite controlS 5059 Generates Spark Until a Pilot Flame is Sensed HEATING FEATURES • Generates spark pulse until flame is sensed through spark electrode. • Begins sparking immediately if flame extinguishes. • Rugged solid state module design. • Spark plug or spike output configurations available. SPECIFICATIONS ...
contact网页The plant has now added the dual ignition requirement to their flare specifications as a standard. NAO flare pilots are available in standard sizes and lengths of 1 1/4″ diameter Conservation Pilot, 2″ diameter Heavy …
contact网页 · White Rodgers 5059-134 - Pilot Relite Control, 1/4" Spade Terminals, 24V Input, Spike Terminal High Voltage Connection - Generates Spark Until a Pilot Flame is Sensed Features Generates spark pulse until flame is sensed through spark electrode Begins sparking immediately if flame extinguishes Rugged solid state module design …
contact网页 · Generates Spark Until a Pilot Flame is Sensed FEATURES • Generates spark pulse until flame is sensed through spark electrode. • Begins sparking immediately if flame extinguishes. • Rugged solid state module design. • Available in 24 and 20 volt input. • Spark plug or spike output configurations available. 5059-23 Pilot Relite Control
contact网页 · The 5059 Pilot Relight Control is a low voltage control that generates ignition sparks. It is energized by the thermo-stat on a call for heat. Once flame is established, the control senses the flame and stops sparking. If the pilot flame is extinguished during a call for heat, the relight control will begin sparking immediately upon sensing
contact网页1/4" Compression, 0.025" Orifice, I Tip Style, Side/End Mounting Bracket, Stainless Steel Electrode Ignition, Flame Rectification, Primary Aerated, Pilot Burner Assembly Q179A is a Gas Pilot Assembly (With a Flame Electrode Rod) and Ignition Electrode, Making it Suitable for Applications Requiring an Interrupted or Intermittent Electrically ...
contact网页 · Pilot Relite Control PILOT RELITE / IGNITION ELECTRODE / FLAME SENSORS SPARK / HSI IGNITION 5059 SERIES PILOT RELITE CONTROLS Generates Spark Until a Pilot Flame is Sensed FEATURES • Generates spark pulse until flame is sensed through spark electrode. • Begins sparking immediately if flame extinguishes. • …
contact网页 · CS100, CS300, and CS600 pilot relite control spark igniters are high voltage spark ignition/flame relay controls and microprocessor based. Should only be used with systems that already have a pilot safety control incorporated.
contact网页Test Circuit. Pilot flame rods work on the ionization / rectification process to complete a circuit. There is always voltage to the flame rod when the power is on. Our relay panel used a small transformer to increase the voltage from 120 VAC to approximately 300 VAC at the flame rod. This voltage is with the pilot off and no presence of flame.
contact网页The Series 2000 pilot flame ignitors and monitors are assemblies that are welded to the ends of ... The spark produced by the electrode ignites the air/gas mixture on the first burner section. ... The Series 2000- MPQ-1 pilot monitor is mounted at the burner location farthest from the point of ignition. The pilot ignites via flame propagation ...
contact网页Generates Spark Pulse Until Flame is Sensed through Spark Electrode; Begins Sparking Immediately if Flame Extinguishes; Rugged Solid State Module Design; Spark Plug or Spike Output Configurations: Manufacturer Name : White-Rodgers: Manufacturer Part Number : 50-59-134S1: Manufacturer Part Number Additional : 5059-134: Series/Model : 5059: …
contact网页SPARK IGNITION pilot relite controlS 5059 Generates Spark Until a Pilot Flame is Sensed HEATING FEATURES • Generates spark pulse until flame is sensed through spark electrode. • Begins sparking immediately if flame extinguishes. • Rugged solid state module design. • Spark plug or spike output configurations available. SPECIFICATIONS ...
contact网页 · Generates Spark Until a Pilot Flame is Sensed FEATURES • Generates spark pulse until flame is sensed through spark electrode. • Begins sparking immediately if flame extinguishes. • Rugged solid state module design. • Available in 24 and 20 volt input. • Spark plug or spike output configurations available. 5059-23 Pilot Relite Control
contact网页 · White Rodgers 5059-134 - Pilot Relite Control, 1/4" Spade Terminals, 24V Input, Spike Terminal High Voltage Connection - Generates Spark Until a Pilot Flame is Sensed Features Generates spark pulse until flame is sensed through spark electrode Begins sparking immediately if flame extinguishes Rugged solid state module design …
contact网页White Rodgers 760-56 Spark Pilot Electrode Flame Sensor Ignition Opens in a new window or tab. New (Other) C $20.52. Top Rated Seller Top Rated Seller. Buy It Now. from United States. Last one. 1 watchers. ... White-Rodgers Automatic Pilot Relite Ignition Control 785-001 Opens in a new window or tab. Pre-Owned. C $39.95. Top Rated Seller Top ...
contact网页 · Here are the five most common reasons your boiler fails on ignition or pilot. 1. Dirty Flame Scanner. Flame scanners need to be inspected and cleaned frequently, at least once a month. Your flame scanner may operate via UV, visible, or infrared light signaling. However, the result of all of these is the same: your flame scanner will sense the ...
contact网页 · Pilot Relite Control PILOT RELITE / IGNITION ELECTRODE / FLAME SENSORS SPARK / HSI IGNITION 5059 SERIES PILOT RELITE CONTROLS Generates Spark Until a Pilot Flame is Sensed FEATURES • Generates spark pulse until flame is sensed through spark electrode. • Begins sparking immediately if flame extinguishes. • …
contact网页Pilot flame ignition system. Computational Study on Micro-Pilot Flame Ignition Strategy for a Direct Injection Stratified Charge Rotary Engine. The Office of Security of Defense's Assured Fuels ...
contact网页 · CS100, CS300, and CS600 pilot relite control spark igniters are high voltage spark ignition/flame relay controls and microprocessor based. Should only be used with systems that already have a pilot safety control incorporated.
contact网页Test Circuit. Pilot flame rods work on the ionization / rectification process to complete a circuit. There is always voltage to the flame rod when the power is on. Our relay panel used a small transformer to increase the voltage from 120 VAC to approximately 300 VAC at the flame rod. This voltage is with the pilot off and no presence of flame.
contact网页Generates Spark Pulse Until Flame is Sensed through Spark Electrode; Begins Sparking Immediately if Flame Extinguishes; Rugged Solid State Module Design; Spark Plug or Spike Output Configurations: Manufacturer Name : White-Rodgers: Manufacturer Part Number : 50-59-134S1: Manufacturer Part Number Additional : 5059-134: Series/Model : 5059: …
contact网页Electrodes & Flame Rods. X04200 Ignition Electrode X04201 FD75 Ignition Electrode 99 X04202 FD75 Flame Rod Electrode 99 ... X04249 Columbia Boiler Extended Electrode X04250 Premix Flame Rod Pilot Electrode. …
contact网页The “Spitfire“ flare pilot is available in a 9 or 12 foot length depending on mounting and flame lick requirements. The “Spitfire“ flare pilot comes standard with Stackmatch Flare Ignition, Inc. patented “ Micro Flame …
contact网页Pilot Relight Kit: Electrode Assembly: Order 10-395: High Voltage Cable: Order 1751-726: Spark Gap: 1/8" Temperature Range-40°F to 185°F: High Voltage Output: 15kV: Electrical Rating: 24/120V AC, 0.1 Amps: …
contact网页I claim 1. In an automatic fuel ignition system including a pilot source for establishing a pilot flame and valve means operable when energized to supply a gaseous fuel to burner apparatus, an electronic control circuit for monitoring the pilot flame and controlling the energization of said valve means, said control circuit comprising pilot flame sensing …
contact网页 · The current remains at a low level as long as the flame front passes ...flame sensor detects the presence of the pilot flame. If the pilot flame goes out (with the thermostat still calling for heat), the G670 will de-energize the main gas valve and provide a continuous spark at the pilot burner’s electrode. When the pilot flame is re-ignited ...
contact